Techfine 12500va Best 10kw Inverter 48v Solar Inverter Support Parallel
Techfine 12500va Best 10kw Inverter 48v Solar Inverter Support Parallel
Feature:
MPPT Efficiency max 98%
Parallel Function Up to Maximum 9 units
Self design PCB board and cooling system
Optional MPPT solar charge controller 120A

Product Details

ModelVS12548   AM8B(support parallel)
System Voltage12500VA
Nominal   Voltage220VAC
Input voltage   range154-265VAC ;   185-264VAC(selectable)
Input   frequency50/60Hz±5% Auto   sensing
Rated power10000W
Battery   Voltage(DC)48V
Output   frequency50Hz/60Hz土1%
WaveformPure sine wave
Ransfer   time(AC to Dc)≤8ms(UPS)/≤20ms(INV)
Load peak   ratio(MAX)3:1
Output Voltage   Regulation10%
Bypass Mode(YES)
Saver Mode(YES)
Battery TypeVRLA/GELIGEL DEEP   CYCLE /LITHIUM
Input   ProtectionInput over current   protection with fuse
Output   ProtectionOverload, short   circuit, High   low voltage, battery   reverse protections
AC Charging   Current60A
Maximum PV   array power48V:MPPT150VDC(Customized   200VDC)
Maximum solar   charge current120A
Maximum solar   Pv Watt6400W
LED Indicator   statusAC Line In:Green   ;Inverter: Green charging:Yellow : Alarm: Red
LCD indicatorAC   input voltage/input frequency, PV voltage,/PV current /output Voltage
   Frequency/Battery voltage/Load current etc.
Low battery   alarmAudible alarm-5   seconds beeping
Overload alarmAudible   alarm-continuous beeping
FaultAudible   alarm-continuous beeping
Storage   temperature-15°C~45°C
Operating   temperature0°C-60°C
Relative   temperature10°C-90°Cno   condensation
Noise(db)<45dB


FAQs

What is the conversion efficiency of your company's photovoltaic modules?

The efficiency of mass-produced TOPCon components reached 24.7% (industry average 23.5%), and the efficiency of laboratory N-type batteries exceeded 26.1% (T Ü V certification)
Double sided component back gain of 30%+, suitable for high reflection ground scenes

How does the component perform in extreme climates such as deserts and extreme cold?

Working in a wide temperature range of -40 ℃~85 ℃, the Norwegian polar project measured that the power generation exceeded the design value by 103% at -30 ℃
Desert environment anti UV aging certification, with an annual attenuation rate of only 0.45% (industry average of 0.8%)

Do you provide customized design solutions for the project? How long is the response cycle?

Provide free system design services (including shadow analysis and IRR calculation)
Standard solution output within 48 hours, complex scenarios (such as offshore microgrids) within 72 hours

Do you support sample testing?

Provide 2 free samples with third-party testing reports attached

Contact us

Submit

Recommended Products